	<title>Vapour recovery system &#8211; Scanair Industrial Chillers</title>
	<atom:link href="https://chillersindia.in/tag/vapour-recovery-system/feed" rel="self" type="application/rss+xml" />
	<link>https://chillersindia.in</link>
	<description>ChillersIndia.in Air chillers, Liquid Chillers and Heat pumps for the demanding cooling applications. Manufacturers and suppliers of Industrial Chillers in India.</description>
	<lastBuildDate>Thu, 30 Mar 2017 17:41:13 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.8.3</generator>

<image>
	<url>https://chillersindia.in/wp-content/uploads/2023/07/favicon.png</url>
	<title>Vapour recovery system &#8211; Scanair Industrial Chillers</title>
	<link>https://chillersindia.in</link>
	<width>32</width>
	<height>32</height>
</image> 
<atom:link rel="hub" href="https://pubsubhubbub.appspot.com"/><atom:link rel="hub" href="https://pubsubhubbub.superfeedr.com"/><atom:link rel="hub" href="https://websubhub.com/hub"/>	<item>
		<title>SOFT DRINK CHILLERS</title>
		<link>https://chillersindia.in/chillers/soft-drink-chillers</link>
		
		<dc:creator><![CDATA[chillersindia]]></dc:creator>
		<pubDate>Thu, 30 Mar 2017 17:41:13 +0000</pubDate>
				<category><![CDATA[Chillers]]></category>
		<category><![CDATA[beverage chillers]]></category>
		<category><![CDATA[poultry hatcheries chillers]]></category>
		<category><![CDATA[reverse osmosis chillers]]></category>
		<category><![CDATA[shrimp hatcheries chillers]]></category>
		<category><![CDATA[soft drink chillers]]></category>
		<category><![CDATA[Vapour recovery system]]></category>
		<guid isPermaLink="false">http://chillersindia.in/?p=200</guid>

					<description><![CDATA[Scanair Soft Drink Chillers manufactured with food grade SS 316L , 304 Grade heat ex-changers in evaporator side By using these high-efficiency heat ex-changers, our chillers save up to 30% in energy consumption compared to internal coils. This chillers are]]></description>
										<content:encoded><![CDATA[<p style="text-align: justify;"><img fetchpriority="high" decoding="async" class="size-full wp-image-202 alignleft" src="http://static.chillersindia.in/uploads/2017/03/soft-drink-chiller.jpg" alt="soft drink chiller" width="288" height="400" srcset="https://chillersindia.in/wp-content/uploads/2017/03/soft-drink-chiller.jpg 288w, https://chillersindia.in/wp-content/uploads/2017/03/soft-drink-chiller-216x300.jpg 216w" sizes="(max-width: 288px) 100vw, 288px" />Scanair Soft Drink Chillers manufactured with food grade SS 316L , 304 Grade heat ex-changers in evaporator side By using these high-efficiency heat ex-changers, our chillers save up to 30% in energy consumption compared to internal coils. This chillers are specially designed for Soft Drinks making Factories. The water should be maintained +2˚C ±0.1˚C resolution before enter in to the carbonator. Then only the soft Drinks batch production CO2 mixing in the water uniformly.</p>
<p style="text-align: justify;">Scanair Soft Drink chillers will maintain the temperature range from 1˚ C To 30˚ C  ± 1˚ C. capacity from 450 Kcal/Hr to 150000 Kcal/Hr with 20 LPH To 5000 LPH different flow capacity. If the water temperature differentials between inlet and outlet are high, then a large external water tank would be used to store the cold water.  In this case the chilled water is not going directly from the chiller to the application, but goes to the external water tank which acts as a sort of “temperature buffer.”  The cold water tank is much larger than internal water tank.  The cold water goes from the external tank to the application and the return hot water from the application goes back to the external tank, not to the chiller. The same application will be followed for liquid like wine, soda, Soft drinks and fruit juices.</p>
<h2 style="text-align: justify;">Refrigeration Chillers</h2>
<p style="text-align: justify;"><img decoding="async" class="size-full wp-image-203 alignleft" src="http://static.chillersindia.in/uploads/2017/03/soft-drink-chillers.jpg" alt="soft drink chillers" width="353" height="376" srcset="https://chillersindia.in/wp-content/uploads/2017/03/soft-drink-chillers.jpg 353w, https://chillersindia.in/wp-content/uploads/2017/03/soft-drink-chillers-282x300.jpg 282w" sizes="(max-width: 353px) 100vw, 353px" />Soft Drink chillers typically come as complete packaged closed-loop systems, including the chiller unit, condenser, and pump station with re-circulation pump, expansion valve, no-flow shutdown, internal cold water tank, and temperature controller.  The internal tank helps maintain cold water temperature and prevents temperature spikes from occurring.  Closed loop Refrigeration chillers will deliver clean RO water with condition flavor at a constant temperature and pressure to increase the stability. The water flows from the chiller to the application’s point like carbonator at pre adjusted temperature in a generously sized heat ex-changer, Scanair Refrigeration chillers guarantee a secure and repeatable production process, while saving you money and protecting the environment.  All Refrigeration chillers use environmentally friendly, non-ozone depleting refrigerant.  Total process security at high efficiency levels makes the Refrigeration chillers the optimum solution, packaged type have been designed for many years of trouble free operation.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>LIQUID CHILLERS</title>
		<link>https://chillersindia.in/chillers/liquid-chillers</link>
		
		<dc:creator><![CDATA[chillersindia]]></dc:creator>
		<pubDate>Thu, 23 Mar 2017 22:59:18 +0000</pubDate>
				<category><![CDATA[Chillers]]></category>
		<category><![CDATA[Anodizing chillers]]></category>
		<category><![CDATA[Food processing chillers]]></category>
		<category><![CDATA[Heat exchangers]]></category>
		<category><![CDATA[Laboratories chillers]]></category>
		<category><![CDATA[Pharmaceutical processing chillers]]></category>
		<category><![CDATA[Vapour recovery system]]></category>
		<guid isPermaLink="false">http://chillersindia.in/?p=159</guid>

					<description><![CDATA[Scanair Liquid Chillers are manufactured under GMP standards, and the evaporators are designed with SS 304, 316 L Grade plate type heat exchangers. Evaporator will facilitate use of internally enhanced high performance tubes and permits liquid to be circulated at]]></description>
										<content:encoded><![CDATA[<p style="text-align: justify;"><img decoding="async" class="size-full wp-image-160 alignleft" src="https://chillersindia.in/wp-content/uploads/2017/03/Liquid-Chiller-1.jpg" alt="Liquid Chiller" width="321" height="300" srcset="https://chillersindia.in/wp-content/uploads/2017/03/Liquid-Chiller-1.jpg 321w, https://chillersindia.in/wp-content/uploads/2017/03/Liquid-Chiller-1-300x280.jpg 300w" sizes="(max-width: 321px) 100vw, 321px" />Scanair Liquid Chillers are manufactured under GMP standards, and the evaporators are designed with SS 304, 316 L Grade plate type heat exchangers. Evaporator will facilitate use of internally enhanced high performance tubes and permits liquid to be circulated at high velocity through the tubes resulting in greater heat transfer and higher operating efficiencies. Because anodizing process generates a lot of heat, cooling is a must, particularly for hard coating processes. Liquid Chillers will do most of the work, removing process heat using either an air or water cooled chiller. Air cooled units are generally installed outside, and eliminate the need for a tower.</p>
<p style="text-align: justify;">Water-cooled units are the most efficient method, particularly in warmer climates. They are installed inside a building with a cooling tower outside.</p>
<div>
<p style="text-align: justify;"><img loading="lazy" decoding="async" class="size-full wp-image-161 alignleft" src="https://chillersindia.in/wp-content/uploads/2017/03/vapour-recovery-system.jpg" alt="vapour recovery system" width="229" height="226" srcset="https://chillersindia.in/wp-content/uploads/2017/03/vapour-recovery-system.jpg 229w, https://chillersindia.in/wp-content/uploads/2017/03/vapour-recovery-system-45x45.jpg 45w" sizes="auto, (max-width: 229px) 100vw, 229px" />Toughened glass heat exchangers to handle direct liquid like Sulfuric Acid (H2SO4), Hydro choleric acid (HCL) and other hazardous liquids in following process. Hard Aluminum anodizing process need the sulfuric acid both to be cool at + 4˚C for excellent performance and higher quality component production. Scanair liquid chillers can handled those liquid directly in to the evaporator get cooled by the special metal like titanium, molybenum steel, copper lead coated tubes, thorough fluid pumps and it is pumped into your process for successful production.</p>
</div>
<div>
<p style="text-align: justify;">Liquid chillers will maintain the temperature range from 0˚ C To + 30˚ C ˚ ± 1˚ C, capacity from 3000 Kcal/Hr to 150000 Kcal/Hr 3 LPM to 650 LPM with different flow capacity. Easy and practical to open side panels for servicing each plumbing, refrigeration accessories, electrical accessories. Compressors incorporate in a variety of safeguards that ensure durability including an internal pressure relief valve, motor temperature protections superior oil management functionality. Liquid Chillers are ozone friendly, packaged types have been designed for many years of trouble free operation. Chillers ideal and most suitable for a wide spectrum of applications in industries like soft drinks, soda, bulk drug manufacturing, fruit, beverages, bakery, laboratories, petrochemical and refineries, distillation process, pharmaceutical, laboratories, R&amp;D Labs etc.,</p>