<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>on line soda water chillers &#8211; Scanair Industrial Chillers</title>
	<atom:link href="https://chillersindia.in/tag/on-line-soda-water-chillers/feed" rel="self" type="application/rss+xml" />
	<link>https://chillersindia.in</link>
	<description>ChillersIndia.in Air chillers, Liquid Chillers and Heat pumps for the demanding cooling applications. Manufacturers and suppliers of Industrial Chillers in India.</description>
	<lastBuildDate>Fri, 14 Jul 2023 14:04:31 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.8.3</generator>

<image>
	<url>https://chillersindia.in/wp-content/uploads/2023/07/favicon.png</url>
	<title>on line soda water chillers &#8211; Scanair Industrial Chillers</title>
	<link>https://chillersindia.in</link>
	<width>32</width>
	<height>32</height>
</image> 
<atom:link rel="hub" href="https://pubsubhubbub.appspot.com"/><atom:link rel="hub" href="https://pubsubhubbub.superfeedr.com"/><atom:link rel="hub" href="https://websubhub.com/hub"/>	<item>
		<title>SODA CHILLERS</title>
		<link>https://chillersindia.in/chillers/soda-chillers</link>
		
		<dc:creator><![CDATA[chillersindia]]></dc:creator>
		<pubDate>Thu, 30 Mar 2017 17:15:24 +0000</pubDate>
				<category><![CDATA[Chillers]]></category>
		<category><![CDATA[fermentation chillers]]></category>
		<category><![CDATA[fish hacheries chillers]]></category>
		<category><![CDATA[food mixing]]></category>
		<category><![CDATA[hydro coolers]]></category>
		<category><![CDATA[on line soda water chillers]]></category>
		<category><![CDATA[ro water chillers]]></category>
		<category><![CDATA[yogurt chillers]]></category>
		<guid isPermaLink="false">http://chillersindia.in/?p=191</guid>

					<description><![CDATA[Scanair Soda Chillers manufactured with food grade SS 316L , 304 Grade heat ex-changers and evaporator, by using high-efficiency heat ex-changers, our chillers save up to 30% in energy consumption compared to internal coils. This chiller is specially designed for]]></description>
										<content:encoded><![CDATA[<p style="text-align: justify;"><img fetchpriority="high" decoding="async" class="size-full wp-image-193 alignleft" src="https://chillersindia.in/wp-content/uploads/2017/03/Soda-chiller.jpg" alt="Soda chiller" width="280" height="450" srcset="https://chillersindia.in/wp-content/uploads/2017/03/Soda-chiller.jpg 280w, https://chillersindia.in/wp-content/uploads/2017/03/Soda-chiller-187x300.jpg 187w" sizes="(max-width: 280px) 100vw, 280px" />Scanair Soda Chillers manufactured with food grade SS 316L , 304 Grade heat ex-changers and evaporator, by using high-efficiency heat ex-changers, our chillers save up to 30% in energy consumption compared to internal coils. This chiller is specially designed for Soda making factories. The water should be maintained +2˚C ± 0.1˚C resolution before entering in to the carbonator.&nbsp; Then only the soda batch production, CO2 will mix with the water uniformly.</p>
<p style="text-align: justify;">Scanair Soda chillers will maintain the temperature range from 1˚ C To 30˚ C ± 1˚ C capacity from 800 Kcal/Hr to 150000 Kcal/Hr with 20LPH to 5000LPH different flow capacity. If the water temperature differentials between inlet and outlet are high, then a large external water tank would be used to store the cold water.&nbsp; In this case the chilled water is not going directly from the chiller to the application, but goes to the external water tank which acts as a sort of temperature buffer or (cold bank). The cold water tank is much larger than the internal water tank.&nbsp; The cold water goes from the external tank to the application and the return hot water from the application goes back to the external tank, not to the chiller.</p>
<p style="text-align: justify;">The same application will be followed for chilling liquids like wine, cooling soft drinks and fruit juices.</p>
<h2 style="text-align: justify;">Refrigeration chillers</h2>
<p><img decoding="async" class="size-full wp-image-194" src="https://chillersindia.in/wp-content/uploads/2017/03/Scanair-Soda-Chillers.jpg" alt="Soda Chillers" width="800" height="500"></p>
<p style="text-align: justify;">Refrigeration chillers typically come as completely packaged closed-loop systems, including the chiller unit, condenser, and pump station with re-circulation pump, expansion valve, no-flow shutdown, internal cold water tank, and temperature controller.&nbsp; The internal tank helps maintain cold water temperature and prevents temperature spikes from occurring.&nbsp; Closed loop Refrigeration chillers will deliver clean RO water with conditioned flavor at a constant temperature and pressure to increase the stability. The water flows from the chiller to the application’s point like carbonator with pre adjusted temperature in a generously sized heat exchanger, Scanair Refrigeration chillers guarantee a secure and repeatable production process, while saving you money and protecting the environment.&nbsp; All refrigeration chillers use environmentally friendly with non-ozone depleting refrigerant.&nbsp; Total process security at high efficiency levels makes the Refrigeration chillers the optimum solution, packaged type have been designed for many years of trouble free operation.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
