	<title>Heat exchangers &#8211; Scanair Industrial Chillers</title>
	<atom:link href="https://chillersindia.in/tag/heat-exchangers/feed" rel="self" type="application/rss+xml" />
	<link>https://chillersindia.in</link>
	<description>ChillersIndia.in Air chillers, Liquid Chillers and Heat pumps for the demanding cooling applications. Manufacturers and suppliers of Industrial Chillers in India.</description>
	<lastBuildDate>Wed, 31 Jan 2018 07:17:22 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.8.3</generator>

<image>
	<url>https://chillersindia.in/wp-content/uploads/2023/07/favicon.png</url>
	<title>Heat exchangers &#8211; Scanair Industrial Chillers</title>
	<link>https://chillersindia.in</link>
	<width>32</width>
	<height>32</height>
</image> 
<atom:link rel="hub" href="https://pubsubhubbub.appspot.com"/><atom:link rel="hub" href="https://pubsubhubbub.superfeedr.com"/><atom:link rel="hub" href="https://websubhub.com/hub"/>	<item>
		<title>REFRIGERATION CHILLERS</title>
		<link>https://chillersindia.in/chillers/refrigeration-chillers</link>
		
		<dc:creator><![CDATA[chillersindia]]></dc:creator>
		<pubDate>Wed, 31 Jan 2018 07:17:22 +0000</pubDate>
				<category><![CDATA[Chillers]]></category>
		<category><![CDATA[Air cooled process chiller]]></category>
		<category><![CDATA[Beverage Equipments]]></category>
		<category><![CDATA[Bio Gas Power Plants]]></category>
		<category><![CDATA[Distillation Processes]]></category>
		<category><![CDATA[Electron Micro scopes]]></category>
		<category><![CDATA[food processing]]></category>
		<category><![CDATA[Heat exchangers]]></category>
		<category><![CDATA[Heat Treatment Equipments]]></category>
		<category><![CDATA[Printing Chillers]]></category>
		<category><![CDATA[Printing Equipments]]></category>
		<category><![CDATA[Refrigeration chillers manufacturers in India]]></category>
		<category><![CDATA[Refrigeration cooling systems]]></category>
		<category><![CDATA[Titanium Water Chiller suppliers in India]]></category>
		<category><![CDATA[vapor recovery systems]]></category>
		<guid isPermaLink="false">http://chillersindia.in/?p=310</guid>

					<description><![CDATA[Scanair compact closed loop refrigeration chillers are designed to supply clean water directly to tip or other lasers requiring distilled or deionizer water. All surfaces in the coolant water loop are either stainless steel, plastic, or other inert material. Chiller]]></description>
										<content:encoded><![CDATA[<p style="text-align: justify;">Scanair compact closed loop refrigeration chillers are designed to supply clean water directly to tip or other lasers requiring distilled or deionizer water. All surfaces in the coolant water loop are either stainless steel, plastic, or other inert material. Chiller has a front panel temperature control which regulates the chilled water from 3°C to 35˚C , and have integral water flow, level, and temperature interlocks. Refrigeration system features hot gas bypass design to extend compressor life, and use CFC free refrigerants. Units are available in 0.5KW to 30 KW versions.</p>
<h2><strong>Refrigeration Chillers in India</strong></h2>
<p><strong> <img fetchpriority="high" decoding="async" class="size-full wp-image-342 alignleft" src="https://chillersindia.in/wp-content/uploads/2018/01/Refrigeration-chiller.png" alt="" width="189" height="501" srcset="https://chillersindia.in/wp-content/uploads/2018/01/Refrigeration-chiller.png 189w, https://chillersindia.in/wp-content/uploads/2018/01/Refrigeration-chiller-113x300.png 113w" sizes="(max-width: 189px) 100vw, 189px" /></strong></p>
<p>&nbsp;</p>
<p style="text-align: justify;">Refrigeration Chillers come as complete packaged closed-loop systems, including the chiller unit, condenser, and pump station with recirculating pump, expansion valve, no-flow shutdown, internal cold water tank, and temperature controller.  The internal tank helps maintain cold water temperature and prevents temperature spikes from occurring.  Closed loop Refrigeration chillers recirculate a clean coolant or clean water with condition addititives at a constant temperature and pressure to increase the stability and reproduce-ability of water-cooled machines and instruments.  The water flows from the chiller to the application’s point of use and back. Scanair Refrigeration chillers guarantee a secure and repeatable production process, while saving you money and protecting the environment.  All Refrigeration chillers use environmentally friendly, non-ozone depleting refrigerant.  Total process security at high efficiency levels makes the Refrigeration chillers the optimum solution.</p>
<p>&nbsp;</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>LIQUID CHILLERS</title>
		<link>https://chillersindia.in/chillers/liquid-chillers</link>
		
		<dc:creator><![CDATA[chillersindia]]></dc:creator>
		<pubDate>Thu, 23 Mar 2017 22:59:18 +0000</pubDate>
				<category><![CDATA[Chillers]]></category>
		<category><![CDATA[Anodizing chillers]]></category>
		<category><![CDATA[Food processing chillers]]></category>
		<category><![CDATA[Heat exchangers]]></category>
		<category><![CDATA[Laboratories chillers]]></category>
		<category><![CDATA[Pharmaceutical processing chillers]]></category>
		<category><![CDATA[Vapour recovery system]]></category>
		<guid isPermaLink="false">http://chillersindia.in/?p=159</guid>

					<description><![CDATA[Scanair Liquid Chillers are manufactured under GMP standards, and the evaporators are designed with SS 304, 316 L Grade plate type heat exchangers. Evaporator will facilitate use of internally enhanced high performance tubes and permits liquid to be circulated at]]></description>
										<content:encoded><![CDATA[<p style="text-align: justify;"><img decoding="async" class="size-full wp-image-160 alignleft" src="https://chillersindia.in/wp-content/uploads/2017/03/Liquid-Chiller-1.jpg" alt="Liquid Chiller" width="321" height="300" srcset="https://chillersindia.in/wp-content/uploads/2017/03/Liquid-Chiller-1.jpg 321w, https://chillersindia.in/wp-content/uploads/2017/03/Liquid-Chiller-1-300x280.jpg 300w" sizes="(max-width: 321px) 100vw, 321px" />Scanair Liquid Chillers are manufactured under GMP standards, and the evaporators are designed with SS 304, 316 L Grade plate type heat exchangers. Evaporator will facilitate use of internally enhanced high performance tubes and permits liquid to be circulated at high velocity through the tubes resulting in greater heat transfer and higher operating efficiencies. Because anodizing process generates a lot of heat, cooling is a must, particularly for hard coating processes. Liquid Chillers will do most of the work, removing process heat using either an air or water cooled chiller. Air cooled units are generally installed outside, and eliminate the need for a tower.</p>
<p style="text-align: justify;">Water-cooled units are the most efficient method, particularly in warmer climates. They are installed inside a building with a cooling tower outside.</p>
<div>
<p style="text-align: justify;"><img decoding="async" class="size-full wp-image-161 alignleft" src="https://chillersindia.in/wp-content/uploads/2017/03/vapour-recovery-system.jpg" alt="vapour recovery system" width="229" height="226" srcset="https://chillersindia.in/wp-content/uploads/2017/03/vapour-recovery-system.jpg 229w, https://chillersindia.in/wp-content/uploads/2017/03/vapour-recovery-system-45x45.jpg 45w" sizes="(max-width: 229px) 100vw, 229px" />Toughened glass heat exchangers to handle direct liquid like Sulfuric Acid (H2SO4), Hydro choleric acid (HCL) and other hazardous liquids in following process. Hard Aluminum anodizing process need the sulfuric acid both to be cool at + 4˚C for excellent performance and higher quality component production. Scanair liquid chillers can handled those liquid directly in to the evaporator get cooled by the special metal like titanium, molybenum steel, copper lead coated tubes, thorough fluid pumps and it is pumped into your process for successful production.</p>
</div>
<div>
<p style="text-align: justify;">Liquid chillers will maintain the temperature range from 0˚ C To + 30˚ C ˚ ± 1˚ C, capacity from 3000 Kcal/Hr to 150000 Kcal/Hr 3 LPM to 650 LPM with different flow capacity. Easy and practical to open side panels for servicing each plumbing, refrigeration accessories, electrical accessories. Compressors incorporate in a variety of safeguards that ensure durability including an internal pressure relief valve, motor temperature protections superior oil management functionality. Liquid Chillers are ozone friendly, packaged types have been designed for many years of trouble free operation. Chillers ideal and most suitable for a wide spectrum of applications in industries like soft drinks, soda, bulk drug manufacturing, fruit, beverages, bakery, laboratories, petrochemical and refineries, distillation process, pharmaceutical, laboratories, R&amp;D Labs etc.,</p>